Use "hot" trip type for thermal zone software shutdown trip for all thermal zones. It just notifies userspace thermal manager which in turn triggers a graceful shutdown. Change-Id: Icf7aa1f1da57a22b96ede18fcee75ebebb92830b Signed-off-by: Manaf Meethalavalappu Pallikunhi <quic_manafm@quicinc.com>
67 lines
1.3 KiB
Plaintext
67 lines
1.3 KiB
Plaintext
// SPDX-License-Identifier: BSD-3-Clause
|
|
/*
|
|
* Copyright (c) 2022-2024 Qualcomm Innovation Center, Inc. All rights reserved.
|
|
*/
|
|
|
|
#include <dt-bindings/interrupt-controller/irq.h>
|
|
#include <dt-bindings/spmi/spmi.h>
|
|
|
|
&spmi_bus {
|
|
#address-cells = <2>;
|
|
#size-cells = <0>;
|
|
interrupt-controller;
|
|
#interrupt-cells = <4>;
|
|
|
|
qcom,pmr735d@a {
|
|
compatible = "qcom,spmi-pmic";
|
|
reg = <0xa SPMI_USID>;
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
pmr735d_tz: pmr735d-temp-alarm@a00 {
|
|
compatible = "qcom,spmi-temp-alarm";
|
|
reg = <0xa00>;
|
|
interrupts = <0xa 0xa 0x0 IRQ_TYPE_EDGE_BOTH>;
|
|
#thermal-sensor-cells = <0>;
|
|
};
|
|
|
|
pmr735d_gpios: pinctrl@8800 {
|
|
compatible = "qcom,pmr735d-gpio";
|
|
reg = <0x8800>;
|
|
gpio-controller;
|
|
#gpio-cells = <2>;
|
|
interrupt-controller;
|
|
#interrupt-cells = <2>;
|
|
};
|
|
};
|
|
};
|
|
|
|
&thermal_zones {
|
|
pmr735d_temp_alarm: pmr735d_tz {
|
|
polling-delay-passive = <100>;
|
|
polling-delay = <0>;
|
|
thermal-governor = "step_wise";
|
|
thermal-sensors = <&pmr735d_tz>;
|
|
|
|
trips {
|
|
pmr735d_trip0: trip0 {
|
|
temperature = <95000>;
|
|
hysteresis = <0>;
|
|
type = "passive";
|
|
};
|
|
|
|
pmr735d_trip1: trip1 {
|
|
temperature = <115000>;
|
|
hysteresis = <0>;
|
|
type = "hot";
|
|
};
|
|
|
|
pmr735d_trip2: trip2 {
|
|
temperature = <145000>;
|
|
hysteresis = <0>;
|
|
type = "critical";
|
|
};
|
|
};
|
|
};
|
|
};
|