// SPDX-License-Identifier: BSD-3-Clause
/*
* Copyright (c) 2022-2024 Qualcomm Innovation Center, Inc. All rights reserved.
*/
#include <dt-bindings/interrupt-controller/irq.h>
#include <dt-bindings/spmi/spmi.h>
&spmi_bus {
#address-cells = <2>;
#size-cells = <0>;
interrupt-controller;
#interrupt-cells = <4>;
qcom,pmr735d@a {
compatible = "qcom,spmi-pmic";
reg = <0xa SPMI_USID>;
#address-cells = <1>;
#size-cells = <0>;
pmr735d_tz: pmr735d-temp-alarm@a00 {
compatible = "qcom,spmi-temp-alarm";
reg = <0xa00>;
interrupts = <0xa 0xa 0x0 IRQ_TYPE_EDGE_BOTH>;
#thermal-sensor-cells = <0>;
};
pmr735d_gpios: pinctrl@8800 {
compatible = "qcom,pmr735d-gpio";
reg = <0x8800>;
gpio-controller;
#gpio-cells = <2>;
interrupt-controller;
#interrupt-cells = <2>;
};
};
};
&thermal_zones {
pmr735d_temp_alarm: pmr735d_tz {
polling-delay-passive = <100>;
polling-delay = <0>;
thermal-governor = "step_wise";
thermal-sensors = <&pmr735d_tz>;
trips {
pmr735d_trip0: trip0 {
temperature = <95000>;
hysteresis = <0>;
type = "passive";
};
pmr735d_trip1: trip1 {
temperature = <115000>;
hysteresis = <0>;
type = "hot";
};
pmr735d_trip2: trip2 {
temperature = <145000>;
hysteresis = <0>;
type = "critical";
};
};
};
};