Add properties to the PM8550VE_F spmi-temp-alarm device to specify it's die temperature ADC channel on Sun power grid V8 boards. This ensures that software is able to read it's precise die temperature instead of estimating it based on the TEMP_ALARM peripheral over-temperature stage. Change-Id: I726e2ca236db94ef8aa7f6c19b3f4c74f745c763 Signed-off-by: David Collins <quic_collinsd@quicinc.com>
70 lines
878 B
Plaintext
70 lines
878 B
Plaintext
// SPDX-License-Identifier: BSD-3-Clause
|
|
/*
|
|
* Copyright (c) 2023-2024 Qualcomm Innovation Center, Inc. All rights reserved.
|
|
*/
|
|
|
|
&VRM_S4J {
|
|
status = "disabled";
|
|
};
|
|
|
|
&S4J {
|
|
status = "disabled";
|
|
};
|
|
|
|
&VRM_S5F {
|
|
status = "ok";
|
|
};
|
|
|
|
&S5F {
|
|
status = "ok";
|
|
};
|
|
|
|
&pm8550vs_f {
|
|
status = "disabled";
|
|
};
|
|
|
|
&pm8550vs_f_temp_alarm {
|
|
status = "disabled";
|
|
};
|
|
|
|
&pm8550ve_f {
|
|
status = "ok";
|
|
};
|
|
|
|
&pm8550ve_f_temp_alarm {
|
|
status = "ok";
|
|
};
|
|
|
|
&pm8550ve_f_tz {
|
|
io-channels = <&pmk8550_vadc PM8550VX_ADC5_GEN3_DIE_TEMP(5)>;
|
|
io-channel-names = "thermal";
|
|
};
|
|
|
|
&S8F_LEVEL {
|
|
regulator-name = "pm_v8f_s8_level";
|
|
};
|
|
|
|
&S8F_LEVEL_AO {
|
|
regulator-name = "pm_v8f_s8_level_ao";
|
|
};
|
|
|
|
&L1F {
|
|
regulator-name = "pm_v8f_l1";
|
|
};
|
|
|
|
&L1F_AO {
|
|
regulator-name = "pm_v8f_l1_ao";
|
|
};
|
|
|
|
&L1F_SO {
|
|
regulator-name = "pm_v8f_l1_so";
|
|
};
|
|
|
|
&L2F {
|
|
regulator-name = "pm_v8f_l2";
|
|
};
|
|
|
|
&L3F {
|
|
regulator-name = "pm_v8f_l3";
|
|
};
|