ARM: dts: qcom: Add PMIC die temp alarm, socd, bcl support for Tuna
Add PMIC die temp mitigation, socd mitigation, bcl support for tuna. Change-Id: I5d6fc37c0b9f4e137510abb1ee4aa3b47cae6005 Signed-off-by: Nitesh Kumar <quic_nitekuma@quicinc.com>
This commit is contained in:
252
qcom/tuna-thermal-overlay.dtsi
Normal file
252
qcom/tuna-thermal-overlay.dtsi
Normal file
@@ -0,0 +1,252 @@
|
||||
// SPDX-License-Identifier: BSD-3-Clause
|
||||
/*
|
||||
* Copyright (c) 2024 Qualcomm Innovation Center, Inc. All rights reserved.
|
||||
*/
|
||||
|
||||
#include <dt-bindings/thermal/thermal_qti.h>
|
||||
|
||||
&thermal_zones {
|
||||
socd {
|
||||
cooling-maps {
|
||||
socd_apc1 {
|
||||
trip = <&socd_trip>;
|
||||
cooling-device = <&APC1_MX_CX_PAUSE 1 1>;
|
||||
};
|
||||
|
||||
socd_cdsp1 {
|
||||
trip = <&socd_trip>;
|
||||
cooling-device = <&cdsp_sw 4 4>;
|
||||
};
|
||||
|
||||
socd_gpu0 {
|
||||
trip = <&socd_trip>;
|
||||
cooling-device = <&msm_gpu 4 4>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pmih010x-bcl-lvl0 {
|
||||
cooling-maps {
|
||||
lbat_modem0 {
|
||||
trip = <&b_bcl_lvl0>;
|
||||
cooling-device = <&modem_bcl 1 1>;
|
||||
};
|
||||
|
||||
lbat_gpu0 {
|
||||
trip = <&b_bcl_lvl0>;
|
||||
cooling-device = <&msm_gpu 1 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pmih010x-bcl-lvl1 {
|
||||
cooling-maps {
|
||||
lbat_modem1 {
|
||||
trip = <&b_bcl_lvl1>;
|
||||
cooling-device = <&modem_bcl 2 2>;
|
||||
};
|
||||
|
||||
lbat_gpu1 {
|
||||
trip = <&b_bcl_lvl1>;
|
||||
cooling-device = <&msm_gpu 2 2>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pmih010x-bcl-lvl2 {
|
||||
cooling-maps {
|
||||
lbat_gpu2 {
|
||||
trip = <&b_bcl_lvl2>;
|
||||
cooling-device = <&msm_gpu 3 3>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pm7550ba-bcl-lvl0 {
|
||||
cooling-maps {
|
||||
vph_0_nr_scg {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&modem_nr_scg_dsc 3 3>;
|
||||
};
|
||||
|
||||
vph_0_nr {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&modem_nr_dsc 6 6>;
|
||||
};
|
||||
|
||||
vph_0_mdm_lte {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&modem_lte_dsc 8 8>;
|
||||
};
|
||||
|
||||
vph_gpu0 {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&msm_gpu 2 2>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pm7550ba-bcl-lvl1 {
|
||||
cooling-maps {
|
||||
vph_1_nr_scg {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&modem_nr_scg_dsc 10 10>;
|
||||
};
|
||||
|
||||
vph_1_nr {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&modem_nr_dsc 9 9>;
|
||||
};
|
||||
|
||||
vph_1_mdm_lte {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&modem_lte_dsc 10 10>;
|
||||
};
|
||||
|
||||
vph_gpu1 {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&msm_gpu 3 3>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pm7550ba-bcl-lvl2 {
|
||||
cooling-maps {
|
||||
vph_gpu2 {
|
||||
trip = <&bcl_lvl2>;
|
||||
cooling-device = <&msm_gpu 7 7>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pmxr2230-bcl-lvl0 {
|
||||
cooling-maps {
|
||||
lbat_0_nr_scg {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&modem_nr_scg_dsc 3 3>;
|
||||
};
|
||||
|
||||
lbat_0_nr {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&modem_nr_dsc 6 6>;
|
||||
};
|
||||
|
||||
lbat_0_mdm_lte {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&modem_lte_dsc 8 8>;
|
||||
};
|
||||
|
||||
lbat_gpu0 {
|
||||
trip = <&bcl_lvl0>;
|
||||
cooling-device = <&msm_gpu 2 2>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pmxr2230-bcl-lvl1 {
|
||||
cooling-maps {
|
||||
lbat_1_nr_scg {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&modem_nr_scg_dsc 10 10>;
|
||||
};
|
||||
|
||||
lbat_1_nr {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&modem_nr_dsc 9 9>;
|
||||
};
|
||||
|
||||
lbat_1_mdm_lte {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&modem_lte_dsc 10 10>;
|
||||
};
|
||||
|
||||
lbat_gpu1 {
|
||||
trip = <&bcl_lvl1>;
|
||||
cooling-device = <&msm_gpu 3 3>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
pmxr2230-bcl-lvl2 {
|
||||
cooling-maps {
|
||||
lbat_gpu2 {
|
||||
trip = <&bcl_lvl2>;
|
||||
cooling-device = <&msm_gpu 7 7>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
sys-therm-0 {
|
||||
cooling-maps {
|
||||
apc1_cdev {
|
||||
trip = <&trip_config0>;
|
||||
cooling-device = <&APC1_MX_CX_PAUSE 1 1>;
|
||||
};
|
||||
|
||||
apc0_cdev {
|
||||
trip = <&trip_config0>;
|
||||
cooling-device = <&APC0_MX_CX_PAUSE 1 1>;
|
||||
};
|
||||
|
||||
cdsp_cdev {
|
||||
trip = <&trip_config0>;
|
||||
cooling-device = <&cdsp_sw 5 THERMAL_NO_LIMIT>;
|
||||
};
|
||||
|
||||
gpu_cdev {
|
||||
trip = <&trip_config0>;
|
||||
cooling-device = <&msm_gpu 5 THERMAL_NO_LIMIT>;
|
||||
};
|
||||
|
||||
cpu3_hot_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&cpu3_hotplug 1 1>;
|
||||
};
|
||||
|
||||
cpu4_hot_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&cpu4_hotplug 1 1>;
|
||||
};
|
||||
|
||||
cpu5_hot_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&cpu5_hotplug 1 1>;
|
||||
};
|
||||
|
||||
cpu6_hot_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&cpu6_hotplug 1 1>;
|
||||
};
|
||||
|
||||
cpu7_hot_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&cpu7_hotplug 1 1>;
|
||||
};
|
||||
|
||||
lte_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&modem_lte_dsc 255 255>;
|
||||
};
|
||||
|
||||
nr_cdev {
|
||||
trip = <&trip_config1>;
|
||||
cooling-device = <&modem_nr_scg_dsc 255 255>;
|
||||
};
|
||||
|
||||
display_cdev1 {
|
||||
trip = <&display_test_config1>;
|
||||
cooling-device = <&display_fps 1 1>;
|
||||
};
|
||||
|
||||
display_cdev2 {
|
||||
trip = <&display_test_config2>;
|
||||
cooling-device = <&display_fps 2 2>;
|
||||
};
|
||||
|
||||
display_cdev3 {
|
||||
trip = <&display_test_config3>;
|
||||
cooling-device = <&display_fps 3 3>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
Reference in New Issue