dt-bindings: thermal: Document pm8550 compatible for bcl pmic5
This change documents pm8550 compatible for bcl pmic5. Change-Id: Ie3528f91d5ebec8c601ec4fc9bbd8037df824b3c Signed-off-by: Minghao Zhang <quic_minghao@quicinc.com>
This commit is contained in:
@@ -23,8 +23,10 @@ description: |
|
||||
|
||||
properties:
|
||||
compatible:
|
||||
const: qcom,bcl-v5
|
||||
description: msm battery state of charge device
|
||||
items:
|
||||
- const: qcom,bcl-v5
|
||||
- const: qcom,pm8550-bcl-v5
|
||||
|
||||
reg:
|
||||
maxItems: 1
|
||||
@@ -96,3 +98,16 @@ examples:
|
||||
qcom,bcl-mon-vbat-only;
|
||||
qcom,pmic7-threshold;
|
||||
};
|
||||
|
||||
bcl@4700 {
|
||||
compatible = "qcom,pm8550-bcl-v5";
|
||||
reg = <0x4700 0x100>;
|
||||
interrupts = <0x1 0x47 0x0 IRQ_TYPE_NONE>,
|
||||
<0x1 0x47 0x1 IRQ_TYPE_NONE>,
|
||||
<0x1 0x47 0x2 IRQ_TYPE_NONE>;
|
||||
interrupt-names = "bcl-lvl0",
|
||||
"bcl-lvl1",
|
||||
"bcl-lvl2";
|
||||
qcom,pmic7-threshold;
|
||||
#thermal-sensor-cells = <1>;
|
||||
};
|
||||
|
Reference in New Issue
Block a user